Patient Admitted With
- Coronary Artery Disease
- Acute Coronary Syndrome
Plan
PTCA / STENTING OF LM-LAD, LCX NANO CRUSH, LCX SZABO
Procedure Approach: Rt Femoral
Procedure Detail
- Using 7F EBU 3.5 guiding catheter, LM ostium was engaged and Run-Through wire was advanced in distal LCX.
- Lesion was pre-dilated with 2.0X15 mm Balloon at 14 atm.
- A 3.0X08 mm Eternia stent was taken.
- Another wire was advanced through 1st strut of stent & anchoring technique done & advanced in distal LAD.
- Finally stent deployed at 14-16 atm, in Ostial LCX Lesion.
- LAD Lesion was pre-dilated with 2.0X15 mm Balloon at 14 atm.
- A 2.75X20 mm Eternia stent was deployed at 14-16 atm.
- In Proximal to Mid LAD Lesion 3.5X28 mm Eternia stent was deployed crushing the overhanging struts of LCX stent.
- 1 M POT was done with 4.5x08 mm balloon at 14-16 atm.
- LCX wire was re-crossed and Ostial LCX was pre-dilated with 2.0X15 mm Balloon.